Delta C2000 Series User Manual page 164

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

1.
Switch off the power supply of VFD-C2000 (690V).
2.
Remove the two screws (shown in Figure 6).
3.
Twist opens the card clip and inserts the slot type screwdriver to the hollow to prize the PCB off
the card clip (shown in Figure 7).
4.
Twist opens the other card clip to remove the PCB (shown in Figure 8).
BR#
R/W
Content
Model name
#0
R
Firmware
#1
R
version
Release date of
#2
R
the version
#11
R/W
Modbus Timeout Pre-defined setting: 500 (ms)
#13
R/W
Keep Alive Time Pre-defined setting: 30 (s)
LED Indicators
LED
Status
POWER
Green
Flashes
LINK
Green
Off
[Figure 6]
[Figure 8]
Set up by the system; read only. The model code of
CMC-MOD01=H'0203
Displaying the current firmware version in hex, e.g. H'0100 indicates the
firmware version V1.00.
Displaying the data in decimal form. 10,000s digit and 1,000s digit are for
"month"; 100s digit and 10s digit are for "day".
For 1 digit: 0 = morning; 1 = afternoon.
Indication
On
Power supply in normal status
Off
No power supply
On
Network connection in normal status
Network in operation
Network not connected
Chapter 8 Optional Cards
Explanation
8-25
[Figure 7]
How to correct it?
--
Check the power supply
--
--
Check if the network cable is
connected