Function Key
1.
2.
HAND ON Key
1.
2.
3.
1.
2.
3.
Descriptions of LED Functions
Steady ON: operation indicator of the AC motor drive, including DC brake, zero speed,
Blinking: drive is decelerating to stop or in the status of base block.
Steady OFF: drive doesn't execute the operation command
Steady ON: stop indicator of the AC motor drive.
Blinking: drive is in the standby status.
Steady OFF: drive doesn't execute "STOP" command.
Operation Direction LED
1. Green light is on, the drive is running forward.
2. Red light is on, the drive is running backward.
3. Twinkling light: the drive is changing direction.
(Only KPC-CE01 support this function)
Steady On: In HAND/LOC mode
Steady Off: In AUTO/REM mode
(Only KPC-CE01Support this function )
Steady On: In AUTO/REM mode
Steady Off: In HAND/LOC mode
The functions keys have factory settings and can be defined by users. The factory settings
of F1 and F4 work with the function list below. For example, F1 is JOG function, F4 is a
speed setting key for adding/deleting user defined parameters.
Other functions must be defined by TPEditor first (please use version 1.40 or above).
TPEditor software can be downloaded at:
http://www.deltaww.com/services/DownloadCenter2.aspx?secID=8&pid=2&tid=0&CID=06&itemID=060302&typeID=1&downloadID=,&title=-- Select
Product Series --&dataType=8;&check=1&hl=en-US
Please refer to instruction for TPEditor in Chapter 10-3.
This key is executed by the parameter settings of the source of Hand frequency and hand
operation. The factory settings of both source of Hand frequency and hand operation are
the digital keypad.
Press HAND ON key at stop status, the setting will switch to hand frequency source and
hand operation source. Press HAND ON key at operation status, it stops the AC motor
drive first (display AHSP warning), and switch to hand frequency source and hand
operation source.
Successful mode switching for KPC-CE01, "HAND" LED will be on; for KPC-CC01, it will
display HAND mode on the screen.
This key is executed by the parameter settings of the source of AUTO frequency and
AUTO operation. The factory setting is the external terminal (source of operation is
4-20mA).
Press Auto key at stop status, the setting will switch to hand frequency source and hand
operation source. Press Auto key at operation status, it stops the AC motor drive first
(display AHSP warning), and switch to auto frequency source and auto operation source.
Successful mode switching for KPC-CE01, "AUTO" LED will be on; for KPC-CC01, it will
display AUTO mode on the screen
standby, restart after fault and speed search.