Delta C2000 Series User Manual page 216

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

LCM Display *
Fault
Keypad flash memory read error
FrEr
kpdFlash Read Er
Fault
Keypad flash memory save error
FSEr
kpdFlash Save Er
Fault
Keypad flash memory parameter
FPEr
error
kpdFlash Pr Er
Fault
Keypad flash memory when
VFDr
read AC drive data error
Read VFD Info Er
Fault
and then power on again the
CPUEr
system.
CPU Error
Chapter 10 Digital Keypad
Description
10-31
Corrective Actions
An error has occurred on keypad's flash memory.
1. Press RESET on the keypad to clear errors.
2. Verify what kind of error has occurred on
keypad's flash memory.
3. Shut down the system, wait for ten minutes,
and then power on again the system.
If none of the solution above works, contact your
authorized local dealer.
An error has occurred on keypad's flash memory.
1. Press RESET on the keypad to clear errors.
2. Press RESET on the keypad to clear errors.
3. Shut down the system, wait for ten minutes,
and then power on again the system.
If none of the solution above works, contact your
authorized local dealer.
Errors occurred on parameters of factory setting.
It might be caused by firmware update.
1. Press RESET on the keypad to clear errors.
2. Verify if there's any problem on Flash IC.
3. Shut down the system, wait for ten minutes,
and then power on again the system.
If none of the solution above works, contact your
local authorized dealer.
Keypad can't read any data sent from VFD.
1. Verify if the keypad is properly connect to the
motor drive by a communication cable such as
RJ-45.
2. Press RESET on the keypad to clear errors.
3. Shut down the system, wait for ten minutes,
and then power on again the system.
If none of the solution above works, contact your
local authorized dealer.
A Serious error has occurred on keypad's CPU.
1. Verify if there's any problem on CPU clock?
2. Verify if there's any problem on Flash IC?
3. Verify if there's any problem on RTC IC?
4. Verify if the communication quality of the
RS485 is good?
5. Shut down the system, wait for ten minutes,
and then power on again the system. If none of
the solution above works, contact your local
authorized dealer.