Chapter 16 PLC Functions Applications
API
INT
129
D
Bit device
X
Y
M
S
D
Notes on operand usage:
Please refer to the function specifications table for each device in
series for the scope of device usage
C2000 Series
P
Word device
K
H
KnX KnY KnM
S: the source device to be transformed. D: results of transformation.
The content of the register designated by S is transformed from a binary
floating point number format into a BIN whole number, and is temporarily
stored in D. The BIN whole number floating point number will be discarded.
The action of this command is the opposite of that of command API 49
(FLT).
When X0=On, the binary floating point number (D1, D0) is transformed into a
BIN whole number, and the result is stored in (D10); the BIN whole number
floating point number will be discarded.
X0
Binary floating point number
number transformation
16-bit command
T
C
D
32-bit command (9 STEP)
DINT
execution type
Flag signal: none
DINT
16-82
BIN whole
Continuous
DINTP
execution type
D0
D10
Pulse