Brake release checking
55
signal
LOCAL/REMOTE
56
Selection
UP/DOWN Key Mode
Settings
0: Up/down by the accel/decel time
1: Up/down constant speed (Pr.02-10)
Constant speed. The Accel. /Decel. Speed of the UP/DOWN Key
Settings
0.001~1.000Hz/ms
These settings are used when multi-function input terminals are set to 19/20. Refer to Pr.02-09
and 02-10 for the frequency up/down command.
Pr11-00, Bit7=1, frequency command is not saved. The frequency command returns to zero
when the drive stops, and the display frequency is 0.00Hz. The frequency command
increase/decrease by using Up/Down key is effective only when the drive is at Running status.
Pr.02-09 set to 0: it will increase/decrease frequency command (F) by the setting of
acceleration/deceleration (Pr.01-12~01-19)
Chapter 12 Description of Parameter Settings
This parameter needs to be used with P02-56. The main purpose is
to make sure if mechanical brake works or not after triggering brake
release command.
If the action is right, mechanical brake will give signal to MI
terminal.
Please check time sequence chart for reference.
Use Pr.00-29 to select for LOCAL/REMOTE mode (refer to
Pr.00-29).
When Pr.00-29 is not set to 0, on the digital keypad KPC-CC01 it
will display LOC/REM status. (It will display on the KPC-CC01 if the
firmware version is above version 1.021).
REM
LOC
12.1-02-10
Bit 0
0
1
Factory Setting: 0
Factory Setting: 0.01