Delta C2000 Series User Manual page 301

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

Chapter 12 Description of Parameter Settings
Output when Frequency
30
< Pr.02-34
Y-connection for the
31
Motor Coil
-connection for the
32
Motor Coil
Zero Speed (actual
33
output frequency)
Zero Speed with Stop
34
(actual output frequency)
Error Output Selection 1
35
(Pr.06-23)
Error Output Selection 2
36
(Pr.06-24)
Error Output Selection 3
37
(Pr.06-25)
Error Output Selection 4
38
(Pr.06-26)
Position Attained
39
(Pr.10-19)
Speed Attained
40
(including zero speed)
41
Multi-position Attained
42
Crane Function
Motor Zero-speed
43
Output (Pr.02-47)
44
Low Current Output
Active when frequency is <Pr.02-34.
Active when PR.05-24=1, when frequency output is lower than
Pr.05-23 minus 2Hz, continues longer than 05-25.
Active when PR.05-24=1, when frequency output is higher than
Pr.05-23 plus 2Hz, continues longer than 05-25.
Active when the actual output frequency is 0. (the drive should be
at RUN mode)
Active when the actual output frequency is 0 or Stop.
Active when Pr.06-23 is ON.
Active when Pr.06-24 is ON.
Active when Pr.06-25 is ON.
Active when Pr.06-26 is ON.
Active when the PG position control point reaches Pr.10-19.
Active when the output frequency reaches frequency setting or
stop.
User can set any three multi-function input terminals to 41. The
current position action status of these three terminals will be
outputted. Example: if setting Pr.02-36~02-38 to 41 and only the
multi-position of the second point has been done. Therefore,
current status is RA (ON), RA (OFF) and MO1 (OFF). In this way,
their status is 010. Bit0 is RA and so on.
MO2
Pr.02-17=41
Pr.04-16
0
Pr.04-18
0
Pr.04-20
0
Pr.04-22
0
Pr.04-24
0
Pr.04-26
0
Pr.04-28
0
Pr.04-30
1
Pr.04-32
1
Pr.04-34
1
Pr.04-36
1
Pr.04-38
1
Pr.04-40
1
Pr.04-42
1
Pr.04-44
1
This function should be used with Pr.02-32, Pr.02-33, Pr.02-34,
Pr.02-57 and Pr.02-58.
Active when setting Pr.07-16=Pr.02-34 and Fcmd > Pr.02-34 and
output current > Pr.02-33 and Time > Pr.02-32.
The example of the crane application is in the following for your
reference.
Active when motor actual speed is less than Pr.02-47.
This function needs to be used with Pr.06-71 ~ Pr.06-73
12.1-02-15
MO1
RY2
Pr.02-16=41
Pr.02-14=41
0
0
0
1
0
1
1
0
1
0
1
1
1
1
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
RY1
Pr.02-13=41
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

690v

Table of Contents