Chapter 12 Description of Parameter Settings
Electrical Gear at Motor Side B2
Settings
Parameters 10-04 to 10-07 can be used with the multi-function input terminal (set to 48) to
switch to Pr.10-04~10-05 or Pr.10-06~10-07 as shown as follows
Treatment for Encoder/ Speed Observer Feedback Fault
Settings
Detection Time of Encoder/ Speed Observer Feedback Fault
Settings
When encoder loss, encoder signal error, pulse signal setting error or signal error, if time
exceeds the detection time for encoder feedback fault (Pr.10-09), the encoder signal error will
occur. Refer to the Pr.10-08 for encoder feedback fault treatment.
When speed controller signal is abnormal, if time exceeds the detection time for encoder speed
controller fault (Pr.10-09), the feedback fault will occur. Refer to the Pr.10-08 for encoder
feedback fault treatment.
Encoder/ Speed Observer Stall Level
Settings
This parameter determines the maximum encoder feedback signal allowed before a fault occurs.
(Max. output frequency Pr.01-00 =100%)
Detection Time of Encoder/ Speed Observer Stall
Settings
1~65535
load
encoder is us ed
at load side
0: Warn and keep operating
1: Warn and RAMP to stop
2: Warn and COAST to stop
0.0~10.0 sec
0: No function
0~120%
0: No function
0.0~2.0 sec
PG
car d
Gear
Gear
B1 or B2
A1 or A2
gear ratio
ON = A2: B2
MI=48
OFF=A 1:B 1
12.1-10-3
Factory Setting: 100
Driv er
Motor
Factory Setting: 2
Factory Setting: 1.0
Factory Setting: 115
Factory Setting: 0.1