Delta C2000 Series User Manual page 300

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

0
No Function
1
Operation Indication
Master Frequency
2
Attained
Desired Frequency
3
Attained 1 (Pr.02-22)
Desired Frequency
4
Attained 2 (Pr.02-24)
Zero Speed (frequency
5
command)
Zero Speed with Stop
6
(frequency command)
7
Over Torque 1
8
Over Torque 2
9
Drive Ready
10
Low voltage warn (Lv)
11
Malfunction Indication
Mechanical Brake
12
Release (Pr.02-32)
13
Overheat
Software Brake Signal
14
Indication
15
PID Feedback Error
16
Slip Error (oSL)
Terminal Count Value
17
Attained (Pr.02-20; not
return to 0)
Preliminary Counter
18
Value Attained
(Pr.02-19; returns to 0)
External Base Block
19
input (B.B.)
20
Warning Output
21
Over-voltage Warning
Over-current Stall
22
Prevention Warning
Over-voltage Stall
23
prevention Warning
Operation Mode
24
Indication
25
Forward Command
26
Reverse Command
Output when Current >=
27
Pr.02-33
Output when Current <
28
Pr.02-33
Output when frequency
29
>= Pr.02-34
Chapter 12 Description of Parameter Settings
Active when the drive is not at STOP.
Active when the AC motor drive reaches the output frequency
setting.
Active when the desired frequency (Pr.02-22) is attained.
Active when the desired frequency (Pr.02-24) is attained.
Active when frequency command =0. (the drive should be at RUN
mode)
Active when frequency command =0 or stop.
Active when detecting over-torque. Refer to Pr.06-07 (over-torque
detection level-OT1) and Pr.06-08 (over-torque detection
time-OT1). Refer to Pr.06-06~06-08.
Active when detecting over-torque. Refer to Pr.06-10 (over-torque
detection level-OT2) and Pr.06-11 (over-torque detection
time-OT2). Refer to Pr.06-09~06-11.
Active when the drive is ON and no abnormality detected.
Active when the DC Bus voltage is too low. (refer to Pr.06-00 low
voltage level)
Active when fault occurs (except Lv stop).
When drive runs after Pr.02-32, it will be ON. This function should
be used with DC brake and it is recommended to use contact "b"
(N.C).
Active when IGBT or heat sink overheats to prevent OH turn off
the drive. (refer to Pr.06-15)
Active when the soft brake function is ON. (refer to Pr.07-00)
Active when the feedback signal is abnormal.
Active when the slip error is detected.
Active when the counter reaches Terminal Counter Value
(Pr.02-19). This contact won't active when Pr.02-20>Pr.02-19.
Active when the counter reaches Preliminary Counter Value
(Pr.02-19).
Active when the output of the AC motor drive is shut off during
base block.
Active when the warning is detected.
Active when the over-voltage is detected.
Active when the over-current stall prevention is detected.
Active when the over-voltage stall prevention is detected.
Active when the operation command is controlled by external
terminal. (Pr.00-21 0)
Active when the operation direction is forward.
Active when the operation direction is reverse.
Active when current is >= Pr.02-33.
Active when current is < Pr.02-33
Active when frequency is >= Pr.02-34.
12.1-02-14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

690v

Table of Contents