Chapter 16 PLC Functions Applications
C2000 Series
After leaving the PLC register window, the register setting screen will appear, as shown below:
If there is a new PLC program and no settings have yet been made, you can read default data from the
converter, and merely edit it to suit the current application. If settings have already been made, however,
the special D in the CANopen area will display the saved status (the CANopen D area is located at D1090
to D1099 and D2000 to D2799). Assuming it is a new program, we will first read the default data from the
converter; check the communications format if there is no communications link (the default PLC station
number is 2, 9600, 7N2, ASCII). Perform the following steps: 1. Switch the PLC to Stop status; 2. Press
the transmit button; 3. click on read memory after exiting the window; 4. Ignore D0-D399; and 5. click on
the confirm button.)
16-122