Big variation of current or
OC while switching
Lower Per Unit of System
Inertia (Pr.11-01)/
Lower ASR1 Low-speed
Bandwidth (Pr.11-03)
Big variation of output
frequency or dissipation
IncreasePM Sensorless
Observer Bandwidth for
High Speed Zone (Pr.10-32)/
Decrease Per Unit of
System Inertia (Pr.11-01)
IPM control method SOP
1. Set up IPM motor
Pr05-33=2
2. Set up motor parameter according to the motor Nameplate
Pr01-01 Output Frequency of Motor 1 base frequency and motor rated frequency
Pr01-02 Output Voltage of Motor 1 base frequency and motor rated frequency
Pr05-34 Full-load current of Permanent Magnet Motor
Pr05-35 Rated Power of Permanent Magnet Motor
Pr05-36 Rated speed of Permanent Magnet Motor
Pr05-37 Pole number of Permanent Magnet Motor
3. Execute Auto-tuning
Set upPr05-00=13 for IPM motor tuning and press Run(static-tuning). When the tuning
is done, the following parameters will be obtained.
Pr05-39 Stator Resistance of PM Motor
Pr05-40 Permanent Magnet Motor Ld
Pr05-41 Permanent Magnet Motor Lq
4. Set up control mode: Pr00-10=0 velocity mode, Pr00-11=7 IPM sensor-less
5. Turn OFF the power and power ON again.
6. Modify the ASR Kp and Ki according to system need.
Chapter 12 Description of Parameter Settings
Set frequency command
(Higher than switching command)
Perform RUN command
Can the drive run
NO
normally until switching
to higher frequency?
When running at high
NO
frequency, is the frequency
stable?
Increase load and Test
Procedure for switching between I
F mode and FOC mode
12.1-10-10
Observe output current
fequency via
Yes
commnucation intreface
Observe output current
fequency via
Yes
commnucation intreface