Encoder Input Type Setting
Settings
0: Disable
1: Phase A leads in a forward run command and phase B leads in a reverse
run command
A
B
2: Phase B leads in a forward run command and phase A leads in a reverse
run command
A
B
3: Phase A is a pulse input and phase B is a direction input. (L =reverse
direction, H=forward direction)
A
B
4: Phase A is a pulse input and phase B is a direction input. (L=forward
direction, H=reverse direction)
A
B
5: Single-phase input
A
Output Setting for Frequency Division (denominator)
Settings
1~255
This parameter is used to set the denominator for frequency division (for PG card EMC-PG01L
or EMC-PG01O). For example, when it is set to 2 with feedback 1024ppr, PG output will be
1024/2=512ppr.
Electrical Gear at Load Side A1
Electrical Gear at Motor Side B1
Electrical Gear at Load Side A2
Chapter 12 Description of Parameter Settings
FWD
FWD
FWD
FWD
12.1-10-2
Factory Setting: 0
REV
REV
REV
REV
Factory Setting: 1