Frame
Model VFD-_ _ _ C63B-00/21
Rated Output Capacity (kVA)
Applicable Motor Output (690V, kW)
Applicable Motor Output (690V, HP)
Applicable Motor Output (575V, HP)
Rated Output Current (A)
Rated Output Capacity (kVA)
Applicable Motor Output (690V, kW)
Applicable Motor Output (690V, HP)
Applicable Motor Output (575V, HP)
Rated Output Current (A)
Rated Output Capacity (kVA)
Applicable Motor Output (690V, kW)
Applicable Motor Output (690V, HP)
Applicable Motor Output (575V, HP)
Rated Output Current (A)
Efficiency (%)
Fundamental wave PF
Carrier Frequency (kHz)
Input current (A) Light duty
Input current (A) Normal duty
Input current (A) Heavy duty
Rated Voltage/Frequency
Operating Voltage Range
Frequency Tolerance
Drive Weight
Cooling method
Braking Chopper
DC reactor
Frame
Model VFD-_ _ _ C63B-00/21
Rated Output Capacity (kVA)
Applicable Motor Output (690V, kW)
Applicable Motor Output (690V, HP)
Applicable Motor Output (575V, HP)
Rated Output Current (A)
Rated Output Capacity (kVA)
Applicable Motor Output (690V, kW)
Applicable Motor Output (690V, HP)
Applicable Motor Output (575V, HP)
Rated Output Current (A)
Rated Output Capacity (kVA)
Applicable Motor Output (690V, kW)
Applicable Motor Output (690V, HP)
Applicable Motor Output (575V, HP)
Rated Output Current (A)
Efficiency (%)
Fundamental wave PF
Carrier Frequency (kHz)
Input current (A) Light duty
Input current (A) Normal duty
Input current (A) Heavy duty
Rated Voltage/Frequency
Operating Voltage Range
Frequency Tolerance
Drive Weight
Cooling method
Braking Chopper
DC reactor
* Three different duty can be selected in pr 00-16: Light duty, normal duty, heavy duty. The default setting is light duty.
C
185
220
300
370
27.6
34.5
41.4
51.5
18.5
22
30
37
25
30
40
50
20
25
30
40
24
30
36
45
23
27.6
34.5
41.4
15
18.5
22
30
20
25
30
40
15
20
25
30
20
24
30
36
16.1
23
27.6
34.5
11
15
18.5
22
15
20
25
30
10
15
20
25
14
20
24
30
97
97
97
97
>0.98 >0.98 >0.98 >0.98 >0.98 >0.98 >0.98 >0.98 >0.98 >0.98 >0.98 >0.98
29
36
43
54
24
29
36
43
20
24
29
36
3 phases AC 525 V~690 V ( -15%~+10%), 50/60 Hz
10 ± 1.5 Kg
Built-in
Optional
G
2500
3150
333.5
402.5
250
315
335
425
250
350
290
350
253
333.5
200
250
270
335
200
250
220
290
207
253
160
200
215
270
150
200
180
220
98
98
>0.98
>0.98
292
353
222
292
181
222
3 phases AC 525 V~690 V ( -15%~+10%), 50/60 Hz
135
4 Kg
9-3
Chapter 9 Specification
D
E
450
550
750
900
62.1
77
98.9 119.6 143.7 172.5
45
55
75
90
60
75
100
125
50
60
75
100
54
67
86
104
51.5
62.1
77
98.9 119.6 143.7 172.5
37
45
55
75
50
60
75
100
40
50
60
75
45
54
67
86
41.4
51.5
62.1
77
30
37
45
55
40
50
60
75
30
40
50
60
36
45
54
67
97
97
97
97
2~9 (Default 4 kHz)
65
81
84
102
54
65
66
84
43
54
53
66
446~759 Vac
47~63 Hz
39 ± 1.5 Kg
61 ± 1.5 Kg
Fan cooling
Optional
Built-in
H
4000
4500
494.5
534.7
400
450
530
600
400
450
430
465
402.5
442.7
315
355
425
475
350
400
350
385
333.5
356.5
250
280
335
375
250
350
290
310
98
98
>0.98
>0.98
2~9 (Default 4kHz)
454
469
353
388
292
313
446~759 Vac
47~63 Hz
243 ± 5 Kg
Fan coling
Optional
Built-in
F
1100 1320 1600 2000
207
253
110
132
160
200
150
175
215
270
125
150
150
200
125
150
180
220
207
90
110
132
160
125
150
175
215
100
125
150
150
104
125
150
180
98.9 119.6 143.7 172.5
75
90
110
132
100
125
150
175
75
100
125
150
86
104
125
150
97
97
97
97
122
147
178
217
102
122
148
178
84
102
123
148
88 ± 1.5 Kg
5600
6300
678.5
776
560
630
745
850
500
675
590
675
534.7
776
450
630
600
850
450
500
465
675
483
776
400
630
530
850
450
500
420
675
98
98
>0.98
>0.98
595
681
504
681
423
681