Delta C2000 Series User Manual page 57

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

Chapter 4 Wiring
4-2 System Wiring Diagram
Power inpu t te rmina l
NFB or f us e
Elect romagnet ic
cont ac tor
AC reactor
(in put terminal)
Zero-phas e
reactor
EMI filt er
R/L1 S/L2 T/L3
E
U/T1 V/T2 W/T3
Zero-ph ase
rea ct or
AC reac tor
(outp ut termin al)
M oto r
Power in put
te rminal
NFB or f use
Elect romagnet ic
con tac tor
A C react or
(inpu t te rmina l)
+
B1
B2
-
E
Zero-phase
reac tor
EMI filt er
B ra ke re sis tor Used to shorte n dec eleration time of the motor.
AC reactor
(outp ut termin al)
P lea se supp ly po we r according to the rate d
po we r spe cificat io ns ind ic ate d in the manua l
(ref er to 9 Spe cificat io ns Table).
There may be a large inrush cu rren t du ring
p owe r on. Re fer t o 7-2 NFB to select a suitab le
NFB or fuse.
Switc hing ON/OFF the primary side of th e
electromagn etic con tactor c an turn the inte grated
elevator d evic e ON/ OFF, but frequ ent switching is
a cause of mac hine failure . Do no t swit ch ON/O FF
more than once an ho ur. Do not use the
electromagn etic con tactor as t he power s witc h
fo r the in tegrat ed elevator d rive; doing so will
s horten the lif e of the in tegrat ed elevator d rive.
When the main power supply ca pacit y is
great er tha n 500k VA, or when it switches
into the phas e capacit or, the in st antane ous
peak v oltage and current gene ra ted will
destroy th e interna l circuit of the motor
drive . It is recomme nded to ins tall an inp ut
sid e AC react or in the mot or drive. This
will a lso improv e the power f ac tor an d reduc e
power h armonics. The wiring dis tance should
be with in 10m.
Pleas e ref er to 7-4.
Us ed to reduce radiat ed inte rf erenc e, espe cially
in en vironment s wit h audio devices, and reduce
input and outpu t side inte rf erence.
The effec tive range is A M ban d to 10MHz.
Please re fer to A ppendix 7-5.
Can be use d to reduce elec tromagne tic
interf erence .
Please refe r to 7-1 .
Th e wiring length of the mot or will a ffect the size
of the reflected wav e on the motor e nd. It is
recommen ded to install an AC reac tor wh en th e
motor wiring lengt h is greate r than 20 met ers.
Re fer t o 7-4.
4-8