Chapter 12 Description of Parameter Settings
76: STO
77: STO Loss 2
78: STO Loss 3
79: U phase over current (Uocc)
80: V phase over current (Vocc)
81: W phase over current (Wocc)
82: OPHL U phase output phase loss
83: OPHL Vphase output phase loss
84: OPHL Wphase output phase loss
85: PG-02U ABZ hardware disconnection
86: PG-02U UVW hardware disconnection
87: oL3
88: Reserved
89: Initial rotor position detection error
90: Inner PLC function is forced to stop
91~100: Reserved
101: CGdE CANopen software disconnect1
102: CHbE CANopen software disconnect2
103: Reserved
104: CbFE CANopen hardware disconnect
105: CIdE CANopen index setting error
106: CAdE CANopen slave station number
setting error
107: CFrE CANopen index setting exceed limit
108~110: Reserved
111: InrCOM Internal communication overtime
error
112: PM sensorless shaft Lock error
113: Reserved
PTC (Positive Temperature Coefficient) Detection Selection
Settings
Pr.06-29 setting defines how the will drive operate after PTC detection.
PTC Level
Settings
It needs to set AVI/ACI/AUI analog input function Pr.03-00~03-02 to 6 (P.T.C. thermistor input
value).
It is used to set the PTC level, and the corresponding value for 100% is max. analog input value.
Fault Code
0: Warn and keep operating
1: Warn and ramp to stop
2: Warn and coast to stop
3: No warning
0.0~100.0%
Bit0
Bit1
current
Volt.
12.1-06-13
Bit2
Bit3
Bit4
OL
SYS
FBK
Factory Setting: 0
Factory Setting: 50.0
Bit5
Bit6
EXI
CE