Chapter 12 Description of Parameter Settings
When the contact is ON, the drive will execute emergency stop and
display EF1 on the keypad. The motor won't run and be in the free
run until the fault is cleared after pressing RESET" (EF: External
Fault)
When is the contact of this function is ON, the drive will operate by
1st V/f.
When the contact of this function is ON, the drive will operate by
2nd V/f.
Refer to Pr.11-30~11-32 for details.
When the contact of this function is ON, the corresponding 15-step
speed for the multi-function inputs 1-4 will be 15 positions. (Refer to
Pr.04-16 to Pr.04-44)