Chapter 16 PLC Functions Applications
API
ZRST
40
Bit device
X
Y
M
D1
D2
Notes on operand usage:
Number of operand D
Operands D
, D
must designate the same type of device
1
2
Please refer to the function specifications table for each device in
series for the scope of device usage
C2000 Series
D1
D2
P
Word device
K
H
KnX KnY KnM
operand
number of operand D
1
D
: Clear range's initial device. D
1
When the number of operand D
designated by D
will be cleared.
2
When X0 is On, auxiliary relays M300 - M399 will be cleared and changed to Off.
When X1 is On, 16-bit counters C0 - C127 will all be cleared. (Writes 0, and clears
and changes contact and coil to Off).
When X10 is On, timer T0 - T127 will all be cleared. (Writes 0, and clears and
changes contact and coil to Off).
When X3 is On, the data in data registers D0 - D100 will be cleared and set as 0.
X0
X1
X10
X3
Devices can independently use the clear command (RST), such as bit device Y, M
and word device T, C, D.
X0
Clear range
16-bit command (5 STEP)
T
C
D
ZRST
32-bit command
2
Flag signal: none
: Clear range's final device.
2
> number of operand D
1
ZRST
M300
ZRST
C0
ZRST
T0
ZRST
D0
RST
RST
RST
16-66
Continuous
ZRSTP
execution type
execution type
, only the operand
2
M399
C127
T127
D100
M0
T0
Y0
Pulse