Advertisement

Chapter 12 Description of Parameter Settings
Output for CANopen
50
control
51
Output for RS-485
Control multi-function output terminals through CANopen.
To control RY2, set Pr02-14 = 50.
The mapping table of the CANopen DO is below:
Setting of
physical
related
terminal
parameters
RY1
P2-13 = 50
RY2
P2-14 = 50
MO1
P2-16 = 50
MO2
P2-17 = 50
MO10
P2-36 = 50
RY10
MO11
P2-37 = 50
RY11
RY12
P2-38 = 50
RY13
P2-39 = 50
RY14
P2-40 = 50
RY15
P2-41= 50
Refer to Chapter 15-3-5 for more information.
Control multi-function output terminals through Delta InnerCom
(on RS485 communication)
Setting of
Physical
related
terminal
parameters
RY1
P2-13 = 51
RY2
P2-14 = 51
MO1
P2-16 = 51
MO2
P2-17 = 51
MO10
P2-36=51
RY10
MO11
P2-37 = 51
RY11
RY12
P2-38 = 51
RY13
P2-39 = 51
RY14
P2-40 = 51
RY15
P2-41= 51
12.1-02-17
Attribute
Corresponding Index
RW
The bit 0 at 2026-41
RW
The bit 1 at 2026-41
RW
The bit 3 at 2026-41
RW
The bit 4 at 2026-41
The bit 5 at 2026-41
RW
The bit 5 at 2026-41
The bit 6 at 2026-41
RW
The bit 6 at 2026-41
RW
The bit 7 at 2026-41
RW
The bit 8 at 2026-41
RW
The bit 9 at 2026-41
RW
The bit 10 at 2026-41
Attribute
Corresponding Address
RW
The bit 0 at 2640
RW
The bit 1 at 2640
RW
The bit 3 at 2640
RW
The bit 4 at 2640
The bit 5 at 2640
RW
The bit 5 at 2640
The bit 6 at 2640
RW
The bit 6 at 2640
RW
The bit 7 at 2640
RW
The bit 8 at 2640
RW
The bit 9 at 2640
RW
The bit 10 at 2640