Delta C2000 Series User Manual page 149

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

Chapter 8 Optional Cards
MI 10~ MI 13
I/O Extension
Card
MO10~MO11
I/O Extension
Card
MI 10~ MI 15
Relay Extension
Card
Terminals
Common for Multi-function input terminals
COM
Select SINK NPN /SOURCE PNP in J1 jumper / external power
supply
Refer to parameters 02-26~02-29 to program the multi-function inputs
MI 10~MI 13.
Internal power is applied from terminal E24: +24 Vdc±5% 200mA, 5W
External power +24 VDC: max. voltage 30 VDC, min. voltage 19 VDC,
30W
ON: the activation current is 6.5mA
OFF: leakage current tolerance is 10 A
Multi-function output terminals (photocoupler)
The AC motor drive releases various monitor signals, such as drive in
operation, frequency attained and overload indication, via transistor
(open collector).
Common for multi-function output terminals MO10,
MO11(photocoupler)
MXM
Max 48 VDC 50mA
Terminals
AC
AC power Common for multi-function input terminal (Neutral)
Refer to Pr. 02.26~ Pr. 02.31 for multi-function input selection
Input voltage: 100~130 VAC
Input frequency: 47~63 Hz
Input impedance: 27 Kohm
Terminal response time:
ON: 10 ms
OFF: 20 ms
Terminals
Refer to Pr. 02.36~ Pr. 02.41 for multi-function output selection
Resistive load:
5A (N.O.) 250 VAC
5A (N.O.) 30 VDC
R10A~R15A
Inductive load (COS 0.4)
R10C~R15C
2.0A (N.O.) 250 VAC
2.0A (N.O.) 30 VDC
It is used to output each monitor signal, such as drive is in
operation, frequency attained or overload indication.
Descriptions
MO10
MO11
MXM
Descriptions
Descriptions
8-10