Delta C2000 Series User Manual page 291

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

Chapter 12 Description of Parameter Settings
Operation speed
16
command form ACI
Operation speed
17
command form AUI
18
Emergency Stop (07-20)
19
Digital Up command
20
Digital Down command
21
PID function disabled
22
Clear counter
Input the counter value
23
(multi-function input
command 6)
24
FWD JOG command
25
REV JOG command
FOCPG/TQCPG mode
26
selection
27
ASR1/ASR2 selection
When the contact of this function is ON, the source of the frequency
will force to be ACI. (If the operation speed commands are set to
AVI, ACI and AUI at the same time. The priority is AVI ACI AUI)
When the contact of this function is ON, the source of the frequency
will force to be AUI. (If the operation speed commands are set to
AVI, ACI and AUI at the same time. The priority is AVI ACI AUI)
When the contact of this function is ON, the drive will ramp to stop
by Pr.07-20 setting.
When the contact of this function is ON, the frequency will be
increased and decreased. If this function is constantly ON, the
frequency will be increased/decreased by Pr.02-09/Pr.02-10.
The frequency command returns to zero when the drive stops, and the
display frequency is 0.00Hz. Select Pr11-00, Bit7=1, frequency is not
saved.
When the contact of this function is ON, the PID function is
disabled.
When the contact of this function is ON, it will clear current counter
value and display "0". Only when this function is disabled, it will
keep counting upward.
The counter value will increase 1 once the contact of this function is
ON. It needs to be used with Pr.02-19.
This function is valid when the source of operation command is
external terminals.
When the contact of this function is ON, the drive will execute
forward Jog command.
When execute JOG command under torque mode, the drive will
automatically switch to speed mode; after JOG command is done,
the drive will return to torque mode.
This function is valid when the source of operation command is
external terminals.
When the contact of this function is ON the drive will execute
reverse Jog command.
When execute JOG command under torque mode, the drive will
automatically switch to speed mode; after JOG command is done,
the drive will return to torque mode.
When the contact of this function is ON: TQCPG mode.
When the contact of this function is OFF: FOCPG mode.
RU N/ STOP
com mand
Mu lti-fun ct ion inpu t
te rm inal is set to 2 6
OFF
(t orque /spee d
m ode swit ch)
s peed
03-00 ~02 =1
com mand
(AVI /AU I/AC I is
fr eq uen cy comma nd)
torque
l i mit
03-00 ~0 2=2
(AVI /AUI /AC I is
torqu e co mman d)
s peed
C ont ro l
c ontrol
mo de
S witc h tim ing for torque/speed c ontr ol
(00-10=0/4, m ulti-function input ter minal is s et t o 26)
When the contact of this function is ON: speed will be adjusted by
ASR 2 setting. OFF: speed will be adjusted by ASR 1 setting. Refer
to Pr.11-02 for details.
12.1-02-5
RUN
ON
OFF
speed li mit
s peed
speed li mit
com mand
t orque
t orque
l imi t
c ommand
comm and
s peed
t orque
tor que
c ontrol
c ontrol
c ont rol
STOP
ON
torque
s peed
c ontrol
(dec el. t o stop)