Delta C2000 Series User Manual page 282

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

It can use suitable brake resistor (see Chapter 06 Accessories) to decelerate in a short time and
prevent over-voltage.
When enabling Pr.01-24~Pr.01-27, the actual accel./decel. time will be longer than the setting.
01-00
Max. O utput
Frequency
Frequency
Setting
JOG Frequency
Settings
0.00~599.00Hz
Both external terminal JOG and key "F1" on the keypad KPC-CC01 can be used. When the jog
command is ON, the AC motor drive will accelerate from 0Hz to jog frequency (Pr.01-22). When
the jog command is OFF, the AC motor drive will decelerate from Jog Frequency to zero. The Jog
Accel./Decel. time (Pr.01-20, Pr.01-21) is the time that accelerates from 0.0Hz to Pr.01-22 JOG
Frequency.
The JOG command can't be executed when the AC motor drive is running. In the same way,
when the JOG command is executing, other operation commands are invalid.
It does not support JOG function in the optional keypad KPC-CE01.
1st/4th Accel./decel. Frequency
Settings
0.00~599.00Hz
The transition from acceleration/deceleration time 1 to acceleration/deceleration time 4, may also
be enabled by the external terminals. The external terminal has priority over Pr. 01-23.
When using this function, please set S-curve acceleration time as 0 if 4
too short.
Chapter 12 Description of Parameter Settings
Frequency
accel. time
01-12,14,16,18,20
Accel./Decel. Time
12.1-01-7
Time
decel. time
01-13,15,17,19,21
Factory Setting: 6.00
Factory Setting: 0.00
th
acceleration time is set