Removing The Fixing Pressure Thermal Switch; Points To Note When Mounting The Fixing Pressure Thermal Switch - Canon iR C6800 Series Service Manual

Hide thumbs Also See for iR C6800 Series:
Table of Contents

Advertisement

9.6.9.2 Removing the Fixing
Pressure Thermal Switch
1) Disconnect the connector [1], and free the harness
[2] from the 4 wire saddles [3].
[2]
[1]
[3]
F-9-139
2) Remove the 2 screws [1], and detach the inlet unit
[2].
[1]
[2]
F-9-140
3) Remove the 2 screws [1], and move the 2 heater
harnesses [2] out of the way.
4) Remove the screw [3], and detach the thermal
switch.
[1]
[2]
F-9-141
0003-0172
[1]
[3]
9.6.9.3 Points to Note When
Mounting the Fixing Pressure
Thermal Switch
After mounting the thermal switch (before
mounting the inlet guide), check to make sure o the
following:
The surface of the thermal switch [1] must be parallel
to the pressure roller. (Be sure to check it by shining
the thermal switch by a pen light.) if not, re mount it.
[1]
F-9-142
OK
NG
NG
NG
F-9-143