Chapter 7
7.9.2 Controlling the Drum Cleaning Unit Drive Mechanism
0003-6412
The drum cleaning unit possesses 2 drive loads; they are controlled by the DC controller, and turned on when the
ITB/drum motor (M2) goes on.
DC-CON
J1109B
M2
F-7-63
1 Magnet roller
2 Waste toner feedscrew
M2: ITB/drum motor
DC CON: DC controller