4) Disconnect the connector [1].
F-7-309
5) Push in the high voltage cable [1] through the
opening [2] indicated in the figure.
[1]
F-7-310
6) While holding the high voltage cable [1] in place as
shown, detach the black developing assembly [2] in
upward direction.
When detaching the black developing assembly,
be sure to work with the high voltage cable kept at the
top of the assembly so that its connector will not
damage the surface of the photosensitive drum.
[1]
[2]
F-7-311
7-120
[1]
[2]
7.11.10.12
Removing
Photosensitive Drum
1) Remove the 2 screws [1], and detach the charging
assembly rail [2].
[1]
F-7-312
2) Remove the screw [1], and detach the charging
assembly rail fixing plate [2].
3) Remove the screw [3], and detach the bearing
stopper [4].
[1]
[2]
[4]
F-7-313
4) Pull the photosensitive drum [1] toward the front
once, and then detach it.
[1]
F-7-314
the
0004-4651
[2]
[3]