Chapter 15
<1EL>
Range of
adjustment
<2EL>
Range of
adjustment
<1TR STS1>
Range of
adjustment
<1TR STS2>
Range of
adjustment
15-102
T-15-143
Use it to set the primary transfer static eliminator bias level.
Check the bias level using DISPLAY>HV STS>1EL; then, use
this mode to set the appropriate bias level.
4000 to 0 (unit: V)
at time of shipment/upon RAM initialization: 0
T-15-144
Use it to set the primary transfer static eliminator bias.
check the bias level using DISPLAY>HV STS>2EL; then, set
the appropriate bias level.
4000 to 0 (unit: V)
at time of shipment/upon RAM initialization: 0
T-15-145
Use it to set the offset value (normal speed) for the primary sheet
to sheet target current.
10 to 10 (unit: 2 yA)
at time of shipment/upon RAM initialization: 0
T-15-146
Use it to set the offset value (1/3 speed) for the primary sheet to
sheet target current.
10 to 10 (unit: 2 yA)
at time of shipment/upon RAM initialization: 0