Chapter 14
14.3.13 E014
Code
Detail
E014
0001
14.3.14 E020
Code
Detail
E020
There is an ATR error.
xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction
xx10
For INIT control (service mode INISET *) at time of initial setup, the Sig value is lower
than 62.
The ATR sensor is damage or has an open circuit. The connector may have poor contact.
The intermediate transfer belt may be soiled.
xx11
For INIT control (service mode INISET *) at time of initial setup, the Sig value is lower
than 62.
The ATR sensor is damaged or has an open circuit. The connector may have poor
contact. The intermediate transfer belt may be soiled>
xx12
For INIT control (service mode INISET *) at time of initial setup, the Sig value is 960
or higher.
The ATR sensor is damaged or has an open circuit. The connector has poor contact. The
opening/closing of the shutter is faulty. The intermediate transfer belt is soiled.
xx13
For INIT control (service mode INISET *) at time of initial setup, the Sig value is lower
than 62.
The ATR sensor is damaged or has an open circuit. The connector has poor contact. The
intermediate transfer belt is soiled.
xx81
When the background (intermediate transfer belt) is read during patch detection, the
P_base_adj value is lower than 255.
The ATR sensor is damaged or has an open circuit. The connector has poor contact. The
ITB cleaner is faulty.
xx90
The result (Sig D) of computation based on the reading of the patch during patch
detection (analog)) is lower than 16.
14-22
Cause/Particulars of detection
There is a fixing motor error.
After motor start up, a lock state is not
identified for 1 sec or more.
Cause/Particulars of detection
T-14-15
Check the fixing motor (fixing assembly); then, turn
off and then on the main power.
T-14-16
Remarks
Remarks
Turn off and then on the main
power; then, execute the
intermediate transfer belt.
Turn off and then on the main
power; then, execute the
intermediate transfer belt.
Turn off and then on the main
power; then, execute the
intermediate transfer belt.
Turn off and then on the main
power; then, execute the
intermediate transfer belt.
Turn off and then on the main
power; then, execute the
intermediate transfer belt.
Turn off and then on the main
power; then, execute the
intermediate transfer belt.
0004-3081