5.4.7.3 Mounting the Scanner
Motor
When mounting the scanner motor, be sure that the
timing belt [3] is securely attached to the scanner
pulley [1] and the motor shaft [2].
[3]
F-5-95
[2]
F-5-96
If the tie wrap [1] of the scanner motor harness is
closer to the motor side than the wire guide [2], the
harness can come into contact with the rotor of the
scanner motor and suffer damage. Be sure that the tie
wrap is closer to the interface PCB than the wire guide
when mounting the scanner motor.
0003-3131
[1]
[3]
[2]
F-5-97
5.4.8 ADF Open/Close Sensor
5.4.8.1 Removing the Reader
Rear Cover
1) Disconnect the connector [1].
[1]
F-5-98
Chapter 5
[1]
0004-5163