Code
Detail
Cause/Particulars of detection
0022
The temperature reaches 80 deg C, but
does not reach 110 deg C within 180 sec.
0023
The temperature reaches 110 deg C, but
doest not reach 140 deg C within 180 sec.
0024
The temperature reaches 140 deg C, but
does not reach 170 deg C within 180 sec.
0025
The temperature reaches 170 deg C, but
does not reach 200 deg C within 180 sec.
If the outside heating roller is in contact,
within 400 sec.
0026
The temperature reaches 200 deg C, but
does not reach 230 deg C within 180 sec.
If the outside heating roller is in contact,
within 400 sec.
0030
After power on, the temperature does not
reach 50 deg C within 420 sec.
0031
The temperature reaches 50 deg C, but
does not reach 80 C deg in 420 sec.
0032
The temperature reaches 80 deg C, but
does not reach 110 deg C within 420 sec.
0033
The temperature reaches 110 deg C, but
does not reach 140 deg C within 420 sec.
The temperature reaches 140 deg C, but
0034
does not reach 170 deg C within 420 sec.
Remarks
Check for an open circuit and poor contact in the main
thermistor, thermal switch, and heater; then, reset in service
mode: COPIER>FUNCTION>CLEAR>ERR.
Check for an open circuit and poor contact in the main
thermistor, thermal switch, and heater; then, reset in service
mode: COPIER>FUNCTION>CLEAR>ERR.
Check for an open circuit and poor contact in the main
thermistor, thermal switch, and heater; then, reset in service
mode: COPIER>FUNCTION>CLEAR>ERR.
Check for an open circuit and poor contact in the main
thermistor, thermal switch, and heater; then, reset in service
mode: COPIER>FUNCTION>CLEAR>ERR.
Check for an open circuit and poor contact in the main
thermistor, thermal switch, and heater; then, reset in service
mode: COPIER>FUNCTION>CLEAR>ERR.
Check for an open circuit and poor contact in the main
thermistor, thermal switch, and heater; then, reset in service
mode: COPIER>FUNCTION>CLEAR>ERR.
Check for an open circuit and poor contact in the main
thermistor, thermal switch, and heater; then, reset in service
mode: COPIER>FUNCTION>CLEAR>ERR.
Check for an open circuit and poor contact in the main
thermistor, thermal switch, and heater; then, reset in service
mode: COPIER>FUNCTION>CLEAR>ERR.
Check for an open circuit and poor contact in the main
thermistor, thermal switch, and heater; then, reset in service
mode: COPIER>FUNCTION>CLEAR>ERR.
Check for an open circuit and poor contact in the main
thermistor, thermal switch, and heater; then, reset in service
mode: COPIER>FUNCTION>CLEAR>ERR.