Chapter 13
13.3.5.6 E070 0102 Error Code
Description
This symptom can occur when paper is placed in the manual feed tray in a low humidity environment and, as a result,
the machine is subjected to static noise.
Cause
If the harness [1] connected to the DC controller PCB is away from the side plate [2] of the DC controller box, wrong
detection (E070 0102) of the ITB home position tends to occur easily because of noise.
Field Remedy
When mounting the DC controller PCB or the DC controller box, be sure to connect the harness to the DC controller
PCB as follows:
1) Connect the connector of the harness [1] first, then the other harness [3].
2) Fix the harnesses [1] [3] in place using the wire saddle [4] so that the harness [1] is on the left side of the other
harness [3].
[4]
[4]
[2]
[4]
[1]
[4]
[3]
F-13-57
13-74
0005-7223