14.3.6 E004
Code
Detail
E004
There is an error in the fixing assembly protection circuit.
There is an open circuit or poor contact in the main thermistor (THM1, THM2, THM3) or sub thermistor (TH4,
THM5, THM6). The AC driver PCB or the DC controller PCB has a fault.
0001
There is an SSR error in the outside heating
roller heater.
0002
There is an SSR error in the fixing sub
heater.
0003
There is an SSR error in the outside heating
roller heater or the fixing sub heater.
0004
There is an SSR error in the fixing main
heater.
0005
There is an SSR error in the outside heating
roller heater or the fixing main heater.
0006
There is an SSR error in the fixing sub heater
or the fixing main heater.
0007
There is an SSR error in the outside heating
roller heater, fixing sub heater, or fixing
main heater.
0008
There is an SSR error in the pressure heater.
0009
There is an SSR error in the outside heating
roller heater or the contact heater.
000A
There is an SSR error in the fixing sub heater
or the contact heater.
000B
There is an SSR error in the outside heating
roller heater, fixing sub heater, or contact
heater.
14-18
Cause/Particulars of detection
T-14-8
Check the main thermistor and the sub thermistor for an open
circuit and poor contact; then, reset in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Check the main thermistor and the sub thermistor for an open
circuit and poor contact; then, reset in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Check the main thermistor and the sub thermistor for an open
circuit and poor contact; then, reset in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Check the main thermistor and the sub thermistor for an open
circuit and poor contact; then, reset in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Check the main thermistor and the sub thermistor for an open
circuit and poor contact; then, reset in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Check the main thermistor and the sub thermistor for an open
circuit and poor contact; then, reset in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Check the main thermistor and the sub thermistor for an open
circuit and poor contact; then, reset in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Check the main thermistor and the sub thermistor for an open
circuit and poor contact; then, reset in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Check the main thermistor and the sub thermistor for an open
circuit and poor contact; then, reset in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Check the main thermistor and the sub thermistor for an open
circuit and poor contact; then, reset in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Check the main thermistor and the sub thermistor for an open
circuit and poor contact; then, reset in service mode:
COPIER>FUNCTION>CLEAR>ERR.
0004-3055