<DEV DC Y>
Use it to check the output value of the developing DC voltage (Y) generated last.
<DEV DC M>
Use it to check the output value of the developing DC voltage (M) generated last.
<DEV DC C>
Use it to check the output value of the developing DC voltage (C) generated last.
<DEV DC K>
Use it to check the output value of the developing DC voltage (K) generated last.
<D CRNT P>
Uses it to indicate the value (P wave) measured of the dark current at time of ATR control.
<D CRNT S>
Uses it to indicate the value (S wave) measured of the dark current at time of ATR control.
<P SENS S>
Use it to check the value (S wave) detected of the intensity of light from the background (drum) at time of ATR
control.
<DENS Y H>
Use it to check the history of measurements taken by the ATR sensor (Y; latest 8 measurements).
<DENS M H>
Use it to check the history of measurements taken by the ATR sensor (M; latest 8 measurements).
<DENS C H>
Use it to check the history of measurements taken by the ATR sensor (C; latest 8 measurements).
<DS S Y H>
Use it to indicate the history of the results of patch image detection (Y; latest 8).
<DS S M H>
Use it to indicate the history of the results of patch image detection (M; latest 8).
<DS S C H>
Use it to indicate the history of the results of patch image detection (C; latest 8).
<P LED DA>
Use it to check the D/A settings of the LED for the path image sensor.
<SPL LG Y>
Use it to indicate the present level of the density reference signal for the Y developing assembly.
<SPL LG M>
Use it to indicate the present level of the density reference signal for the M developing assembly.
<SPL LG C>
Use it to indicate the present level of the density reference signal for the C developing assembly.
<PSENS S>
Use it to indicate the measurement of the background at time of analog patch operation (S wave component).
<PSENS P>
Use it to indicate the measurement of the background at time of analog patch operation (P wave component).
15-32
0005-8976
0005-8969
0005-8970
0005-8971
0005-8977
0005-8972
0001-0159
0005-8978
0005-8973
0005-8974
0004-9549
0005-8962
0005-8963
0001-1023
0004-9551
0005-8964
0005-8965
0005-7928
0004-9555

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir c6800c

Table of Contents