<DMAX M>
Use it to set an offset value for the M density control target value.
Method of Adjustment
Set an offset value for the Y density control value while in 2D MAX control.
range of settings: 8 to 8
at time of shipment/upon RAM initialization: 0
<DMAX C>
Use it to set an offset value for the C density control target value.
Method of Adjustment
Set an offset value for the Y density control target value while in 2D MAX control.
range of settings: 8 to 8
at time of shipment/upon RAM initialization: 0
P TG Y
Use it to set an offset value for the ATR control target value (Y).
Method of Adjustment
Set an offset value for the target value of the Y toner while in ATR control.
range of settings: 108 to 108
at time of shipment/upon RAM initialization: 0
P TG M
Use it to set an offset value for ATR control target value (M).
Method of Adjustment
Set an offset value for the target value of the Y toner density while in ATR control.
range of settings: 108 to 108
at time of shipment/upon RAM initialization: 0
P TG C
Use it to set an offset value for the target value of the Y toner density while in ATR control.
range of settings: 108 to 108
at time of shipment/upon RAM initialization: 0
15.4.4.1.3 V CONT
<VCONT Y>
Method of
adjustment
Range of
adjustment
Attention
T-15-120
Use it to adjust the target contrast potential (yellow).
A higher setting causes the images to be darker.
50 to +50 (unit: 10 V)
[at time of shipment/after RAM initialization: 0]
Avoid its use as much as possible if the operation is normal.
Chapter 15
0005-6849
0005-6848
0005-6732
0005-6846
0005-6845
0002-8349
15-93

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir c6800c

Table of Contents