7) Remove the mounting screw [16], and
detach the cover [17].
8) Detach the feeding belt [18] and the
postcard belt [19].

9.5.2 Removing the Fixing/Feeding Unit Releasing Lever Switch

1) Slide the fixing/feeding unit out of the
machine.
2) Remove the feeding right cover and the
feeding left cover.
3) Disconnect the two connectors [1], and
remove the screw [2]; then, detach the
harness guide [3].
4) Remove the two mounting screws [4],
and detach the fixing/feeding unit re-
leasing lever support [5].
5) Remove the two mounting screws [6],
and detach the releasing lever switch
[7].
COPYRIGHT © 2000 CANON INC.
Download Free Service Manual at http://printer1.blogspot.com
2000 2000 2000 2000
CANON iR5000/iR6000 REV.0 JULY 2000
CHAPTER 5 PICK UP/FEEDING SYSTEM
[19]
[17]
F05-905-05
[3]
F05-905-06
[5]
[4]
F05-905-07
F05-905-08
[18]
[16]
[1]
[2]
[1]
[4]
[7]
[6]