9.3.2 Controlling the Fixing Roller Temperature

9.3.2.1 Overview

Each of the heat rollers of the fixing assembly is controlled based on the output of the main thermistor mounted in
contact with the center of the roller. The sub thermistor mounted in contact with the edge of the roller is used to detect
overheating at the edge of the roller, which can occur when small size paper (e.g., A4R) is move past continuously.
The mechanisms used to control these individual heat rollers are as follows:
DC controller PCB
M4
9-12
J1105-A2
J1105-A3
J1105-A4
J1105-A5
J1105-A7
J1105-A8
J1105-A9
J1105-A10
SL2
H4
H1
H2
H3
M22
MAIN_HEAT_ON
J1810-18
MAIN_TR_ERR
J1810-17
SUB_HEAT_ON
J1810-16
SUB_TR_ERR
J1810-15
PRESS_HEAT_ON
J1810-13
PRESS_TR_ERR
J1810-12
EX_HEAT_ON
J1810-11
EX_TR_ERR
J1810-10
THM3
THM1
THM6
THM2
TP1
TP2
F-9-9
AC driver PCB
TP3
THM4
THM5
0003-2893