12.1 Image Adjustment Basic Procedure

12.1.1 Image Adjustment Basic Procedure 1

The image adjustment basic procedure consists of the following steps:

Image Adjustment Basic Procedure 1

Turn off the potential control mechanism:
COPIER>OPTION>BODY>P0-CNT '0'
Execute the following:
COPIER>FUNCTION>
DPC>OFFSET.
Turn off the main power switch.
1. Short circuit CP82 found on the DC controller PCB and GND (frame).
2. Disconnect the connector J426 for the DC controller PCB found on
the potential control PCB.
Turn on the main power switch.
Make the following selections in service mode:
COPIER>DISPLAY>DPOT>DPOT-K.
Is the setting between
F-12-1
*1: Make a Bk mono copy. If the said fault is absent, make a full color copy. (Be sure not to make more than 5 full
color copies.)
START
NO
Is the image better?
See*1
YES
NG
OK
NO
0 and 30?
YES
Replace the potential
sensor unit.
To image adjustment
basic procedure 2
Check the potential
sensor harness.
Replace the DC
controller PCB.