Canon iR C6800 Series Service Manual page 1001

Hide thumbs Also See for iR C6800 Series:
Table of Contents

Advertisement

14.3.5 E003
Code
Detail
E003
0041
0042
0043
0051
0052
0053
Cause/Particulars of detection
After standby, the drop in the temperature of the fixing assembly is excessive.
There is an open circuit or poor contact in the main thermistor (THM1, THM2, THM3), thermal switch
(TP1, TP2, TP3), or heater (H1, H2, H3, H4). The AC driver PCB or the DC controller PCB has a fault.
During standby, the temperature of the fixing
roller drops below 150 deg C.
During standby, the temperature of the
outside heating roller drops below 190 dg C.
During standby, the temperature of the
pressure roller drops below 120 deg C.
During copying, the temperature of the fixing
roller drops below 150 deg C.
During copying, the temperature of the
outside heating roller drops below 190 deg C.
During copying, the temperature of the
pressure roller drops below 60 deg C.
T-14-7
Check the main thermistor, thermal switch, and heater
for an open circuit and poor contact; then, reset in
service mode: COPIER>FUNCTION>CLEAR>ERR.
Check the main thermistor, thermal switch, and heater
for an open circuit and poor contact; then, reset in
service mode: COPIER>FUNCTION>CLEAR>ERR.
Check the main thermistor, thermal switch, and heater
for an open circuit and poor contact; then, reset in
service mode: COPIER>FUNCTION>CLEAR>ERR.
Check the main thermistor, thermal switch, and heater
for an open circuit and poor contact; then, reset in
service mode: COPIER>FUNCTION>CLEAR>ERR.
Check the main thermistor, thermal switch, and heater
for an open circuit and poor contact; then, reset in
service mode: COPIER>FUNCTION>CLEAR>ERR.
Check the main thermistor, thermal switch, and heater
for an open circuit and poor contact; then, reset in
service mode: COPIER>FUNCTION>CLEAR>ERR.
Chapter 14
0004-3018
Remarks
14-17