7.11.7.4 Sliding Out the
Process Unit
1) Disconnect the 5 connectors [1] found at the upper
right.
[1]
[1]
F-7-179
2) Disconnect the 5 connectors [1] found at the upper
left.
[1]
[1]
F-7-180
3) After freeing the high voltage connector cable [1]
from the 2 wire saddles [2], fix the cable in place using
the cable hook [3].
[2]
[1]
F-7-181
0003-2493
[1]
[3]
4) Take out the process unit cover [1] from the
shipping box, and detach the drum stop tool [2] from
the back of the cover.
[1]
[2]
F-7-182
5) While forcing the drum stop tool [3] against the
drum fixing member [2] of the drum shift [1], remove
the fixing screw [4].
1: Be sure to match the protrusion [5] of the drum
fixing member and the protrusion [6] of the drum stop
tool.
[2]
[4]
[3]
[5]
F-7-183
2: When drawing out the process unit, be sure to find
out the position of the protrusion [1] of the drum
fixing member in relation to the marking [2] on the
drum flange.
In the example in the figure, the marking [2] on the
drum flange is at "." on the left and at ".." on the right
in relation to the protrusion [2] of the drum fixing
member.
Chapter 7
[1]
[6]
7-93