Chapter 15
15.5.1.10 CLEAR
15.5.1.10.1 Overview
Resetting RAM/Error Code/Jam History/Error History
15.5.1.10.2 <ERR>
Method of
operation
15.5.1.10.3 <DC CON>
Caution
Method of
operation
15-126
T-15-203
Use it to reset an error code.
(E000, E001, E002, E003)
1) Select the item, and press the OK key.
2) Turn off and then on the main power supply.
T-15-204
Use it to reset the RAM on the DC controller PCB.
The contents of the RAM are removed when the main power switch is turned off and
then on once again.
1) Obtain a printout of the service mode settings by making the following selections:
COPIER>FUNCTION>MISC P>P PRINT.
2) Select the item, and press the OK key.
3) Turn off and then on the main power.
4) As necessary, enter the data indicated on the print obtained using [P PRINT].
0001-0281
0001-0283
0001-0285