5.4.12.10 Removing the
Scanner Drive Cable
1) Remove the 2 screws [1], and detach the reading
glass retainer [2].
When removing the reading glass retainer, take care
so that the leaf spring will not come off.
2) Remove the reading glass [3].
3) Remove the 2 screws [4], and detach the left glass
retainer [5].
[3]
[4]
[2]
[1]
[4]
F-5-141
When fitting it, be sure to hold down both ends of the
leaf spring [A] with your fingers. (Take care not to
bend the leaf spring.)
Be sure to fit it while forcing the left glass retainer [B]
against the reading glass [C].
Check to make sure that the side of the reading glass
and the leaf spring [D] of the left glass retainer are in
firm contact.
Otherwise, dust from the reading glass can start to
collect, causing lines in images.
0004-1362
[5]
[A]
F-5-142
[C]
[D]
[B]
F-5-143
Chapter 5
5-47