Chapter 7
2) Open the 8 cable clamps [1], and move the harness
[2] out of the way.
[2]
F-7-194
3) Disconnect the connector [1].
[1]
F-7-195
4) Remove the 4 screws [1], and detach the
photosensitive drum cleaning unit [2].
[2]
[1]
F-7-196
7-96
[1]
7.11.7.7 Points to Note When
Mounting the Photosensitive
Drum Cleaning Unit
When mounting the photosensitive drum cleaning
unit, take care not to rotate it in reverse direction to
prevent soiling by the scoop up sheet. (The drum is
designed to rotate counterclockwise.)
7.11.8 Photosensitive Drum
7.11.8.1 Removing the Right
Color (upper)
1) Remove the 2 screws [1], and detach the right cover
(upper) [2].
[1]
F-7-197
7.11.8.2 Releasing the Front
Cover
1) Open the front cover.
2) While pulling on the grip [1], fully open the manual
feed cover [2] to the front.
[1]
F-7-198
0003-8364
0003-8251
[2]
0003-2487
[2]