Chapter 7
Moreover, when you close the process unit, it is
important that the spatial relationship between the
protrusion of the drum fixing member and the
marking on the drum flange is as it was before you
drew out the unit.
6) Using a pair of fine pliers, remove the drum fixing
member [1].
F-7-184
7) Remove the 3 binding screws (M4x8) [1].
[1]
F-7-185
8) Shift down the fixing/feeding assembly releasing
lever [1] in the direction of the arrow.
F-7-186
7-94
[1]
[1]
9) Slide out the fixing/feeding assembly [1] toward
the front.
[1]
F-7-187
10) While pushing on the 2 hooks [1] found on both
sides of the fixing/feeding assembly, fully slide out
the fixing/feeding assembly [2].
[1]
F-7-188
11) Slightly lift both ends [1] of the process unit, and
fully slide out the process unit [2].
[2]