<1TR STS3>
Range of
adjustment
<PRE TR Y>
Range of
adjustment
<PRE TR M>
Range of
adjustment
<PRE TR C>
Range of
adjustment
T-15-147
Use it to set the offset value (2/3 speed) for the primary transfer
sheet to sheet target value.
10 to 10 (unit: 2 yA)
at time of shipment/upon RAM initialization: 0
T-15-148
Use it to adjust the current (Y) for the pre transfer charging assembly.
set the current offset value (Y) of the pre transfer charging assembly.
range of settings: 200 to 200 (in increments of 1)
at time of shipment/upon RAM initialization; 0
T-15-149
Use it to adjust the current (Y) for the pre transfer charging assembly.
Set the offset value (M) for the pre transfer charging assembly.
range of settings: 200 to +200 (in increments of 1)
at time of shipment/upon RAM initialization; 0
T-15-150
Use it to adjust the current level (Y) for the pre transfer charging assembly.
Use it to set the current offset value (C) for the pre transfer charging assembly.
range of settings: 200 to +200 (may be in units of 1's)
at time of shipment/upon RAM initialization: 0
Chapter 15
0005-6911
0005-6912
0005-6913
0005-6916
15-103