Fitting The Scanner Drive Cable - Canon iR C6800 Series Service Manual

Hide thumbs Also See for iR C6800 Series:
Table of Contents

Advertisement

Chapter 5
16) Remove the 2 cable fixing screws [2] of the No. 1
mirror base [1].
17) Remove the spring [3] used to hold the cable in
place.
18) Free the 2 hooks of the cable from the right side of
the reader frame.
19) Free the cable from the pulleys.
[2]
[1]
[4]
[3]
F-5-155
5.4.12.11 Fitting the Scanner
Drive Cable
1) Fit the ball of the cable in the hole of the drive
pulley [1], and wind the cable (4 times inside, 5 times
outside); then, fix it in place using tape or the like. At
this time, be sure that the cable fixing [2] is on the
inside.
2) Engage the cable on the pulleys; then, engage one
end of the cable on the hook [3] of the left side and the
other end on the hook of the right side.
3) Temporarily fix the cable fixing plate [2] in place
to the No. 1 mirror base [5].
4) Mount the reader upper frame.
5-50