Setting, Monitoring, And Testing Through Gx Works2; Compatibility With The Ld77Mh/Qd75Mh; Forced Stop Function - Mitsubishi Electric QD77MS User Manual

Hide thumbs Also See for QD77MS:
Table of Contents

Advertisement

(7) Setting, monitoring, and testing through GX Works2

Parameters and positioning data for the QD77MS can be set using GX Works2
(Simple Motion Module Setting).
Moreover, using the test function of GX Works2 (Simple Motion Module Setting),
users can check the wiring status and the validity of the preset parameters and
positioning data by performing test operation before creating a program for
positioning control.
The control monitor function of GX Works2 allows user to debug programs
efficiently.
The servo parameters can be set easily by using the GX Works2 in combination
with the MR Configurator2.

(8) Compatibility with the LD77MH/QD75MH

The proven programs in LD77MH/QD75MH can be used because the QD77MS
is compatible with the LD77MH/QD75MH.

(9) Forced stop function

The batch forced stop is available for all axes of servo amplifier by the forced
stop signal.
"Valid/Invalid" of the forced stop input signal can be selected by the parameters.
(10) Connection between the QD77MS and servo amplifier with high
speed synchronous network by SSCNET (/H)
The QD77MS can be directly connected to the Mitsubishi servo amplifiers of
MR-J4-B/MR-J3-B series using the SSCNET (/H) . Also, it can be directly
connected to the Mitsubishi servo amplifiers of MR-JE-B series using the
SSCNET /H.
(a) Because the high speed synchronous network by SSCNET (/H) is used
to connect the QD77MS and the servo amplifier, or servo amplifiers,
saving wiring can be realized. The maximum distance between the
QD77MS and servo amplifier, servo amplifier and servo amplifier of the
SSCNET
(SSCNET )/100(328.08) [m(ft.)] (SSCNET /H), and the flexibility will
improve at the system design.
(b) By the use of SSCNET
electromagnetic noise and others from servo amplifier, etc. are reduced.
(c) The servo parameters can be set on the QD77MS side to write or read
them to/from the servo amplifier using the SSCNET communication.
(d) The actual current value and error description contained in the servo can
be checked by the buffer memory of the QD77MS.
(e) The communication between the MR Configurator2 and servo amplifiers is
possible via the PLC CPU.
cable on the same bus was set to 50(164.04) [m(ft.)]
cable (Optical communication), influence of
1 - 4
Chapter 1 Product Outline

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents