SERVICE PROGRAM MODE

4.2.2 SERVICE PROGRAM MODE TABLES

NOTE: 1) In the Function column, comments are in italics.
2) In the Settings column, the default value is in bold letters.
3) S and B in the right hand side of the mode number column means that
this mode is stored in the NVRAM on the SICU (S) or BCU (B). If you do
a RAM reset, all these SP modes will be reset to their factory settings.
4) [A294 I], [A295 I], [A294 II] and [A295 II] in the Settings column mean
the following product types:
[A294 I]: Existing 85 cpm model. [A295 I]: Existing 105 cpm model.
[A294 II]: Enhanced 85 cpm model. [A295 II]: Enhanced 105 cpm
model.
Mode No.
(Class 1, 2 and 3)
1-001
Leading Edge Registration
Paper Tray
1
(Copier and
LCT)
2
Duplex Tray
1-002
Side-to-Side Registration
1
Tray-1
2
Tray-2
SM
CÓPIA NÃO CONTROLADA
Adjusts the printing leading edge
registration for feeding from the trays using
the trimming area pattern (SP2-902-3,
No.15).
B Use the "•" key to toggle between + and –
before entering the value.
The specification is 3 ± 2 mm.
See "Replacement and Adjustment – Copy
Image Adjustments" for details.
Adjusts the printing leading edge
registration for the duplex feeding using the
trimming area pattern (SP2-902-3, No.15).
Use the "•" key to toggle between + and –
before entering the value.
B
The specification is 3 ± 2 mm.
See "Replacement and Adjustment – Copy
Image Adjustments" for details.
Adjusts the printing side-to-side registration
from the 1st paper feed station using the
trimming area pattern (SP2-902-3, No.15).
B Use the "•" key to toggle between + and –
before entering the value.
See "Replacement and Adjustment – Copy
Image Adjustments" for details on SP1-002.
Adjusts the printing side-to-side registration
from the 2nd paper feed station using the
trimming area pattern (SP2-902-3, No.15).
Use the "•" key to toggle between + and –
before entering the value.
B
The specification is 0 ± 2.0 mm.
4-12
CÓPIA NÃO CONTROLADA
Function
Rev. 9/2001
Settings
+9 ~ –9
0.1 mm/step
+3.0 mm
+9 ~ –9
0.1 mm/step
–1.5 mm
+9 ~ –9
0.1 mm/step
–1.5 mm