9 = 0
10 = 0
12 = 0
16 = 0
17 = 0
18 = 0
19 = 0
22 = 0
23 = 0
32 = 0
45 = 0
76 = 0
5.5
Deactivating program test
There are several program test options to test and run-in a part program that are executed
using the "Program Test" function.
This function is active as standard. You can select the program test in the "Machine" operating
area, in the "Program control" window and using the "PRT" check box.
Deactivating the program test
You can deactivate the program test using the following configuration machine data. "PRT" is
no longer displayed in the status line.
MD51039 $MNS_PROGRAM_CONTROL_MODE_MASK
Bit 0 = 0
The test option is described in the following documentation:
References
Function Manual, Basic Functions, Mode Group, Channel, Program Operation, Reset Behavior
(K1)
5.6
Activating the "Teach In" function
Activate TEACH IN
The TEACH IN function is activated in part via the general configuration machine data.
SINUMERIK Operate
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3
; Feed enable missing
; Dwell time active
; Axis enable missing
; Waiting for other channel
; Waiting for feedrate override
; Error in NC block
; Waiting for external NC blocks
; Spindle enable missing
; Axis feedrate override
; Oscillation active
; Search target found
; Wait: G64 still U
Function program test not available
Customizing the "Machine" operating area
5.6 Activating the "Teach In" function
Options for machine - program
control
55