Advanced Settings - Siemens SINUMERIK 828D Commissioning Manual

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

Alarm display
MSG
Entry
MSG
ALARM
Date/time
No.
Deletion criterion:
Text
DETAILS
Example
MSG
10.6.6

Advanced settings

You define the size of the log file of the action log in the "actlog.ini" configuration file.
SINUMERIK Operate
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3
ALARM
No.
Deletion criterion
DETAILS
Description
Type of alarm: ALARM_ON, ALARM_OFF, ALARM_ACK
Data and time of the event
Alarm number
Information as to how the alarm was acknowledged
AUTOMATIC
Automatic acknowledgement
POWER ON
Acknowledgement using PowerOn
RESET
Acknowledgement using NCK reset
NC START
Acknowledgement using NC start
NC RESET
Acknowledgement using NC reset
ALARM CANCEL
Acknowledgement using Alarm Cancel key
RECALL
Acknowledgement using the Recall key
HMI
Acknowledgement using HMI
PLC
Acknowledgement using PLC
Display of the English alarm text
If additional information regarding an entry is known.
ALARM_ON
8020
POWER ON
: Option 'activation of more than 1 channels' not
set
DETAILS:
Mode: JOG Program: canceled Channel: interrupted
Program-Level information:
Level Program running:
1
/_N_MPF0
Service and diagnostics
Date/time
Text
20.02.2009
Invoc
0
10.6 Action log
14:25:37
Offset
0
371