Siemens SINUMERIK 828D Commissioning Manual page 763

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

Load configuration
As described in the "Storage location in the operating area" column in the previous "Files for
configuration" table, the generated files must be copied to the appropriate subdirectories in
the manufacturer's folder.
Note
As soon as there is a script file "xmldial.xml" in the subdirectory for applications, the user can
start this user dialog in the <CUSTOM> operating area.
After the initial copying process, the control system needs to be reset via "Normal power-up".
Example of a user dialog in SINUMERIK Operate
The configured softkey menus are displayed when the <CUSTOM> operating area is called.
This enables the user to operate the dialog forms which have been configured.
Figure 1-5
Further examples are provided in the toolbox.
See also
Predefined functions (Page 81)
Easy XML
Programming Manual, 10/2015, 6FC5397-3DP40-5BA3
Example of a user dialog in the <CUSTOM> operating area
Generating user dialogs
1.3 Configuration files