Siemens SINUMERIK 828D Commissioning Manual page 703

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

Pulses enabled
The message whether the pulses have been enabled for the drive corresponds to the interface
signal:
DB390x, ... DBX4001.7 "Pulses enabled".
Status
1
0
Drive ready
The display of the current status of the selected drive corresponds to the interface signal:
DB390x, ... DBX4001.5 "Drive ready".
Status
1
0
Ramp-up phase
The display of the current ramp-up phase of the selected drive corresponds to the drive
parameter:
r0002 "Drive operating display".
Number of faulty signs-of-life
Display of communications errors detected in hardware between NC and drive.
Note
If the display shows a value other than "0", please contact your Siemens regional office!
SC1 drive alarm message
Displays (yes/no) whether messages of status class 1 are active. Status class 1 messages
are alarms with the following properties:
● They lead to internal responses (e.g. regenerative braking, immediate pulse suppression)
● They are modal.
This is a group message. For details on the actually pending drive alarms, please refer to the
"Drive System Diagnostics" window, see Service drive (Page 333).
SINUMERIK Operate
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3
Meaning
The drive module pulses are enabled. The axis/spindle can now be traversed. Yes
The drive module pulses are suppressed. The axis/spindle can therefore not
be traversed.
Meaning
The drive is ready.
The drive is not ready.
Service and diagnostics
10.2 Displaying the Service overview
Display
No
Display
Yes
No
335

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents