Modifiable parameters
The following parameters of the company network interface (X130) can be set:
● Address type
● IP address
● Subnet mask
● DNS server 1 and 2
● Gateway (applies for service interface and company network)
Address types
● DHCP
The values for the settable parameters IP address, subnet mask, DNS server 1, DNS server
2 and gateway are defined automatically by the DHCP server, in accordance with the entry
in the "basesys.ini".
● Manual
The values for the set parameters IP address, subnet mask, DNS server 1, DNS server 2
and gateway can be specified manually. The values are stored in "basesys.ini".
Procedure
SINUMERIK Operate
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3
1.
Select the "Diagnostics" operating area.
2.
Press the menu forward key and the "Bus TCP/IP" softkey.
3.
Press the "TCP/IP diagnostics" and TCP/IP config." softkeys.
The "TCP/IP Configuration" window opens.
4.
Press the "Modify" softkey to change specific parameters.
The fields that can be edited have a white background.
5.
Enter the desired changes and press the "OK" softkey to confirm the
entries.
6.
Press the "New display" softkey to refresh the display.
Configuring the network
4.4 Station-related network diagnostics
43