MD28450 $MC_MM_TOOL_DATA_CHG_BUFF_SIZE
= 100
MD19320 $ON_TECHNO_FUNCTION_MASK
= 10H
Bit 4
9.1.2

Configuring the access levels of the tool management

Access levels for selected parameters
MD51199 $MNS_ACCESS_WRITE_TM_GRIND
MD51200 $MNS_ACCESS_WRITE_TM_GEO
MD51201 $MNS_ACCESS_WRITE_TM_WEAR
MD51202 $MNS_ACCESS_WRITE_TM_WEAR_DELTA
MD51203 $MNS_ACCESS_WRITE_TM_SC
MD51204 $MNS_ACCESS_WRITE_TM_EC
MD51205 $MNS_ACCESS_WRITE_TM_SUPVIS
MD51206 $MNS_ACCESS_WRITE_TM_ASSDNO
MD51207 $MNS_ACCESS_WRITE_TM_WGROUP
MD51208 $MNS_ACCESS_WRITE_TM_ADAPT
MD51209 $MNS_ACCESS_WRITE_TM_NAME
MD51210 $MNS_ACCESS_WRITE_TM_TYPE
The access level of individual parameters can be overlaid through settings in the
<PARAMETERCONFIGURATION> tag, "Access level" entry (see SectionConfiguring list
parameters (Page 249)).
SINUMERIK Operate
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3
Number of entries in the buffer for the OPI change service for tool data. Dynamic memory
is used. This buffer is only created if either bit 2 or bit 3 is set in MD17530 $MN_TOOL_DA‐
TA_CHANGE_COUNTER.
Enables the tool monitoring function with magazine management.
Tool management
9.1 Machine data for tool management
Buffer for changing tool data (DRAM).
Access level, write TM grinding data.
Access level, write TM geometry data.
Access level, write TM wear data.
Access level, restricted writing of tool
wear values.
Access level, write TM additive offsets.
Access level, write TM operating off‐
sets.
Access level, write TM monitoring data.
Access level, write TM unique D num‐
ber.
Access level, write TM wear groups
(magazine location / magazine).
Access level, write TM tool adapter ge‐
ometry data.
Access level, write TM tool name and
duplo.
Access level, write TM tool type.